arXiv reaDer
Robust COVID-19 Detection in CT Images with CLIP
In the realm of medical imaging, particularly for COVID-19 detection, deep learning models face substantial challenges such as the necessity for extensive computational resources, the paucity of well-annotated datasets, and a significant amount of unlabeled data. In this work, we introduce the first lightweight detector designed to overcome these obstacles, leveraging a frozen CLIP image encoder and a trainable multilayer perception (MLP). Enhanced with Conditional Value at Risk (CVaR) for robustness and a loss landscape flattening strategy for improved generalization, our model is tailored for high efficacy in COVID-19 detection. Furthermore, we integrate a teacher-student framework to capitalize on the vast amounts of unlabeled data, enabling our model to achieve superior performance despite the inherent data limitations. Experimental results on the COV19-CT-DB dataset demonstrate the effectiveness of our approach, surpassing baseline by up to 10.6% in `macro' F1 score in supervised learning. The code is available at https://github.com/Purdue-M2/COVID-19_Detection_M2_PURDUE.
updated: Fri Mar 15 2024 01:21:14 GMT+0000 (UTC)
published: Wed Mar 13 2024 20:26:50 GMT+0000 (UTC)
参考文献 (このサイトで利用可能なもの) / References (only if available on this site)
被参照文献 (このサイトで利用可能なものを新しい順に) / Citations (only if available on this site, in order of most recent)
Amazon.co.jpアソシエイト