arXiv reaDer
A New Method of Pixel-level In-situ U-value Measurement for Building Envelopes Based on Infrared Thermography
The potential energy loss of aging buildings traps building owners in a cycle of underfunding operations and overpaying maintenance costs. Energy auditors intending to generate an energy model of a target building for performance assessment may struggle to obtain accurate results as the spatial distribution of temperatures is not considered when calculating the U-value of the building envelope. This paper proposes a pixel-level method based on infrared thermography (IRT) that considers two-dimensional (2D) spatial temperature distributions of the outdoor and indoor surfaces of the target wall to generate a 2D U-value map of the wall. The result supports that the proposed method can better reflect the actual thermal insulation performance of the target wall compared to the current IRT-based methods that use a single-point room temperature as input.
updated: Sat Jan 13 2024 21:46:31 GMT+0000 (UTC)
published: Sat Jan 13 2024 21:46:31 GMT+0000 (UTC)
参考文献 (このサイトで利用可能なもの) / References (only if available on this site)
被参照文献 (このサイトで利用可能なものを新しい順に) / Citations (only if available on this site, in order of most recent)
Amazon.co.jpアソシエイト